comp.lang.idl-pvwave archive
Messages from Usenet group comp.lang.idl-pvwave, compiled by Paulo Penteado

Home » Public Forums » archive » Re: 100 user units to correspond to exactly 2 cm on the hard copy
Show: Today's Messages :: Show Polls :: Message Navigator
E-mail to friend 
Return to the default flat view Create a new topic Submit Reply
Re: 100 user units to correspond to exactly 2 cm on the hard copy [message #12774] Thu, 03 September 1998 00:00
davidf is currently offline  davidf
Messages: 2866
Registered: September 1996
Senior Member
Kristian Kjaer (kristian.kjaer@risoe.dk) writes:

> On a hard-copy (postscript) plot, how does one get the plot window (the
> area inside the box, where the data points roam) to be, say, precisely
> 10 by 12 cm?

Set_Plot, 'PS'
Device, XSize=10/0.8, YSize=12/0.8, XOffset=4.0, YOffset=6
Plot, Findgen(101), Position=[0.1, 0.1, 0.9, 0.9]

Cheers,

David
----------------------------------------------------------
David Fanning, Ph.D.
Fanning Software Consulting
E-Mail: davidf@dfanning.com
Phone: 970-221-0438, Toll-Free Book Orders: 1-888-461-0155
Coyote's Guide to IDL Programming: http://www.dfanning.com/
[Message index]
 
Read Message