Helder writes:
> I don't see any other reason for this. It could be something in my code, but I can't pin point it (The plot command does not call any function whilst passing parameters). The code is almost 2000 lines and growing, therefore I don't append it, but here are the lines creating the problem:
>
> TPostDraw = SYSTIME(1)
> PlotS, [devcoord[0], devcoord[0]], [(*(self.yCommonPlotRange))[0], (*(self.yCommonPlotRange))[1]], Color=GetColor, Thick=2.0, LineStyle=2, /data
> PlotS, [(*(self.xCommonPlotRange))[0], (*(self.xCommonPlotRange))[1]], [DevCoord[1], DevCoord[1]], Color=GetColor, Thick=2.0, LineStyle=2, /data
> TPlotS = SYSTIME(1)
I would be extraordinarily surprised if this doesn't
turn out to be programmer error in the end. What
are those pointers pointing to? What kind of
color is "GetColor"?
Cheers,
David
--
David Fanning, Ph.D.
Fanning Software Consulting, Inc.
Coyote's Guide to IDL Programming: http://www.dfanning.com/